General presentation
The plugs and couplers are used to connect consummers at the electrical network. They are ideal/suited for mounting in industrial buildings/spaces, building sites, workhouses, industrial production sites or other spaces that require equipments with a high level of stress/strain.
They are made of high quality materials, compliant with european standard EN 60309-2.
Technical details
Standard: |
EN 60309-2 |
Rated voltage: |
230V; 400V AC |
Rated frequency: |
50Hz |
Rated current: |
16A, 32A, 63A |
Poles number: |
2P+PE 3P+N+PE  |
Protection contact position on the clock face: |
18 hour |
Colors: |
230V: blue and white |
400V: red and white |
Protection degree: |
IP 44; IP 67 |
Plastic material: |
Polyamide 66 |
Self extinguishing up to: |
850 °C (for active parts) |
Temperature: |
between -50 °C and +80 °C (fireproof) |
UV resistant. |
Maximum section for the conductors at terminals.
|
Rigid conductor |
Flexible conductor |
In (A) |
Smax(mm2) |
Smax(mm2) |
16 |
10 |
4 |
32 |
16 |
6 |
63 |
25 |
16 |
Coupler on cable:
 |
 |
Type/Sizes |
A |
B |
C |
Ø |
30496 2x16A/IP44 |
42 |
104 |
|
5 |
40100 3x16A/IP44 |
59 |
122 |
51 |
6 |
40101 3x32A/IP44 |
75 |
139 |
64 |
8 |
40102 3x63A/IP67 |
110 |
232 |
68 |
110 |
40103 5x16A/IP44 |
72 |
130 |
64 |
8 |
40104 5x32A/IP44 |
84 |
143 |
70 |
8 |
40105 5x63A/IP67 |
108 |
232 |
68 |
110 |
Coupler on cable:
 |
 |
Type/Sizes |
A |
B |
C |
Ø |
30497 2x16A/IP44 |
57 |
101 |
46 |
5 |
40150 3x16A/IP44 |
68 |
131 |
50 |
22 |
40151 3x32A/IP44 |
92 |
150 |
65 |
24 |
40152 5x16A/IP44 |
90 |
139 |
63 |
24 |
40153 5x32A/IP44 |
100 |
154 |
70,5 |
24 |
40154 3x63A/IP67 |
115 |
240 |
38 |
108 |
40155 5x63A/IP67 |
115 |
240 |
38 |
108 |
Plug embedded in the panel:
 |
 |
 |
Type/Sizes |
A |
B |
C |
ØD |
Ød |
E |
F |
G |
H |
ØI |
30498 2X16/IP44 Shuko |
50,6 |
65 |
41 |
45 |
– |
– |
– |
38,5 |
38,5 |
5 |
40200 3x16A/IP44 |
63 |
70,5 |
37 |
49 |
10,5 |
33 |
81 |
49 |
49 |
10,5 |
40201 3x32A/IP44 |
80 |
99 |
40 |
64,5 |
14 |
38 |
100 |
62 |
72 |
13 |
40202 5x16A/IP44 |
80 |
86 |
43 |
63 |
11,5 |
28 |
100 |
60 |
74 |
13 |
40203 5x32A/IP44 |
97 |
97 |
53 |
70 |
11,5 |
37 |
110 |
50 |
85 |
13,5 |
Applied plug:
 |
 |
Type/Sizes |
A |
B |
C |
D |
E |
F |
G |
40250 3x16A/IP44 |
50 |
92 |
50 |
135 |
57 |
33 |
58 |
40251 3x32A/IP44 |
65 |
102 |
65 |
152 |
57 |
33 |
57 |
40252 3x63A/IP67 |
108 |
134 |
108 |
311 |
111 |
153 |
111 |
40253 5x16A/IP44 |
63 |
100 |
63 |
139 |
63 |
33 |
57 |
40254 5x32A/IP44 |
70 |
107 |
70 |
153 |
70 |
33 |
57 |
40255 5x63A/IP67 |
108 |
134 |
108 |
311 |
111 |
153 |
111 |
Instructiuni de montaj
To access the plugs or couplers terminals, unfasten the screws on the casing/carcass/case.
Connect to conductors to the plug’s or coupler’s terminals according to the inscription/visual instructions.
Previous to fixing the built-in plugs, a cut-out must be made in the panel.
After the cut-out, fix it using screw bolts.