Terminal block blue 1,5mm² 17,5A FJ1,5N

Terminal block blue 1,5mm² 17,5A FJ1,5N

Elvon code: 41881 Technical details: [default_table] Type FJ1.5N Insulation voltage: 8kV Voltage: 500V Rated current at 40°C: 16A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 0,14 – 1,5 Flexible section: 0,14

Terminal block blue 2,5 mm² 32A FJ 3N

Terminal block blue 2,5 mm² 32A FJ 3N

Elvon code: 41882 Technical details: [default_table] Type FJ3N Insulation voltage: 8kV Working voltage: 800V Rated current at 40°C: 32A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 0,2 – 4 Flexible section:

Terminal blocks blue 4mm² 41A FJ5N

Terminal blocks blue 4mm² 41A FJ5N

Elvon code: 41883 Technical details: [default_table] Type FJ5N Insulation voltage: 8kV Voltage: 800V Rated current at 40°C: 40A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 0,2 – 6 Flexible section: 0,2

Terminal blocks blue 6mm² 57A FJ6N

Terminal blocks blue 6mm² 57A FJ6N

Elvon code: 41884 Technical details: [default_table] Type FJ6N Insulation voltage: 8kV Voltage: 800V Rated current at 40°C: 50A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 0,2 – 10 Flexible section: 0,2

Terminal block blue 10mm² 76A FJ10N

Terminal block blue 10mm² 76A FJ10N

Elvon code: 41885 Technical details: [default_table] Type FJ10N Insulation voltage: 8kV Voltage: 800V Rated current at 40°C: 70A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 0,5 – 16 Flexible section: 0,5

Terminal block blue 16mm² 100A FJ16N

Terminal block blue 16mm² 100A FJ16N

Elvon code: 41886 Technical details: [default_table] Type FJ16N Insulation voltage: 8kV Voltage: 800V Rated current at 40°C: 100A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 2,5 – 25 Flexible section: 4

Terminal block blue 35mm² 125A FJ35N(L)

Terminal block blue 35mm² 125A FJ35N(L)

Elvon code: 41887 Technical details: [default_table] Type FJ35N(L) Insolation voltage: 8kV Voltage: 1000V Rated current at 40°C: 125A Electrical contact material: Copper braid Insulation material: PA66 Flammability class according to UL94 V0 Rigid section: 0,75 – 35 Flexible section: 0,75

Terminal block blue 50mm² 150A FJ50

Terminal block blue 50mm² 150A FJ50

Elvon code: 41888 Technical details: [default_table] Type FJ50 Insolation voltage: 8kV Voltage: 1000V Rated current at 40°C: 150A Electrical contact material: Copper braid Isolation material: PA66 Flammability class according to UL94 V0 Rigid section: 16 – 50 Flexible section: 25

Terminal block blue 95mm² 232A FJ95

Terminal block blue 95mm² 232A FJ95

Elvon code: 41889 Technical details: [default_table] Type FJ95 Insolation voltage: 8kV Voltage: 1000V Rated current at 40°C: 192A Electrical contact material: Copper braid Insolation material: PA66 Flammability class according to UL94 V0 Rigid section: 16 – 70mm² Flexible section: 25

Terminal block blue 95mm² 232A FJ95

Terminal block blue 95mm² 232A FJ95

Elvon code: 41890 Technical details: [default_table] Type FJ95 Insolation voltage: 8kV Voltage: 1000V Rated current at 40°C: 230A Electrical contact material: Copper braid Insolation material: PA66 Flammability class according to UL94 V0 Rigid section: 25 – 95 Flexible section: 35